COMMANDER MULTI-PUMP CENTRAL CONTROL SYSTEM
IDMS MANUFACTURES INDUSTRIAL MULTI-PUMP CENTRAL OPERATOR CONTROL SYSTEMS TO MEET SPECIFIC HIGH PERFORMANCE DEMANDS.
Features include:
COMMANDER Fleet unit Interface
Interconnect suitecase enclosure
- Weather-tight suitcase with sealed construction
- Integral stainless steel engraved panel
- MIL spec twist lock bulk head & cable end connections
- Permanently engraved instrument grouping & gauge labeling
- Detachable remote data cable connection with molded plastic strain relief
- Detachable molded remote cable with strain relief x 200′
Control / Data Van installed Digital Operator Interface
Commander TRICON-III Digital CAN-Bus (J1939) Pump Control Operator Control Interface includes:
Central, Touch-screen Data Display (Master Control Unit)
Control features:
- Digital engine / transmission/ Pump/ Fan drive run data module
- Major component specific display screens
- Diagnostics error message display & light indicators
- Control power OFF/ON switch
- Engine OFF/RUN/START switch
- Engine throttle speed UP/DOWN rotary control knob
- E-KILL button (emergency engine / transmission shutdown)
Transmission Group (internally mounted)
- Digital range, error message data & diagnostics display module
Pump Data Screen
- Digital data includes:
- Over pressure trip set point
- Lube oil temperature
- Lube oil pressure
- BBL/Min rate
- Input speed rpm
- Plunger Lube Auto/Manual switch
Environmentally sealed display & components include:
- Digital operator’s color display screen data to include:
- Engine speed (rpm)
- Engine coolant temperature (w/ alarm field/text)
- Engine oil pressure (w/ alarm field/text)
- Engine hours
- Battery Voltage
- Fuel Temperature
- Fan drive pump charge pressure
- Fan drive system main pressure
- Fan drive system oil temperature
- Transmission range (w/ lock-up indicator field/text)
- Transmission oil temperature (w/ alarm field/text)
- Pump oil temperature (w/ alarm field/text)
- Pump oil pressure (w/ alarm field/text)
- Error message text display
- Error message code display (J1939, SPN/FMI)
- Pump over pressure trip set point
- Pump rate (BBL/ min)
- Control power OFF/ON switch
- Engine KILL/RUN/START switch
- Engine throttle speed UP/DOWN rotary control knob
- E-KILL switch (emergency engine/transmission shutdown)
- Transmission range selector
- Transmission instant neutral/ idle button
- Pump over pressure set trip point (Pump screen)